Air Testing & Leakage
Air Pressure Testing is not just for new-builds, it can be used to find leakage areas in existing buildings, improve the air tightness and improve/stop drafts..more
Part L1B
Conservation of fuel and power in Existing Dwellings

Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.
Air Leaking Testing Across the UK
Do I Need An Air Leakage Test?
We offer air leakage testing throughout the UK where our experienced assessors will be happy to offer advice on the best ways to gain your air permeability rating. Planning your test in advance will help us determine how many tests you'll need ahead of time per property.
All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, over a certain size, must have a passing air leakage certificate before the property can be sold.
Part L of the Government building regulations explains that on a large plot of new houses that are built to a similar specification, only a sample of the houses will need to be air tested.
What Does An Air Leakage Test Involve?
An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results. Please note: an air test cannot be carried out if wind speed is more than 13mph. 3 metres per second is the ideal wind speed when undertaking an air test in the UK.
During an air test in the UK the pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut. Furniture will not be affected during the test, but smaller items such as paper must be held down or removed completely so they're not blown about.
There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.
When Should The Test Take Place?
A building envelope will need to be completed before the air test takes place - which should be one of the last surveys undertaken once all the walls, windows, doors etc. are complete and sealed. This ensures no air will escape and prevent drafts through the property which will in-turn improve your air permeability score.
What Air Permeability Rating Do I Need?
Your air permeability rating resembles the amount of uncontrolled air that's leaking from the dwelling. A passing score in the UK is 10 m³/(h.m²). If the air test fails, we will help you identify where these leakage areas occur in the hope that a passing rate will be achieved following a re-test.
How Many Properties Need An Air Tightness Test?
If you have 4 or less properties of the same type then only one test needs to be undertaken per type. If you have more than 4 but less than 40 dwellings of a type then you need at least two tests to be done on each type. Finally, if there are more than 40 properties of a particular type then at least 5% of each type needs to be tested UNLESS the first 5 get a passing score - then this can be dropped to just 2%.
Warning: count(): Parameter must be an array or an object that implements Countable in /data04/elite/public_html/Office.php on line 755
For further Air-Testing information for your area, be sure to check out Air-Testing-.co.uk.
Our other services include:
Warning: Invalid argument supplied for foreach() in /data04/elite/public_html/Office.php on line 769
Air Testing can also be known as:
Domestic Air Integrity Testing, Air Integrity Testing, Domestic Air Leakage Testing, Air Leakage Testing, Domestic Fan Pressure Testing, House Leakage Testing, Domestic Air Pressure Testing, Domestic Air Tightness Testing, Air Pressure Testing, Fan Pressure Testing, Domestic Air Testing, Domestic House Leakage Testing, Air Tightness Testing,
Copyright 2025 E2 Specialist Consultants Limited
Company No. 06728970
In Area I
Domestic AIR Tightness Tests in Ibstock, Domestic AIR Tightness Tests in Ilchester, Domestic AIR Tightness Tests in Ilford, Domestic AIR Tightness Tests in Ilfracombe, Domestic AIR Tightness Tests in Ilkeston, Domestic AIR Tightness Tests in Ilkley, Domestic AIR Tightness Tests in Ilminster, Domestic AIR Tightness Tests in Immingham, Domestic AIR Tightness Tests in Ince-in-Makerfield, Domestic AIR Tightness Tests in Ingatestone, Domestic AIR Tightness Tests in Ingleton, Domestic AIR Tightness Tests in Inkberrow, Domestic AIR Tightness Tests in Innerleithen, Domestic AIR Tightness Tests in Insch, Domestic AIR Tightness Tests in Inveraray, Domestic AIR Tightness Tests in Invergordon, Domestic AIR Tightness Tests in Inverkeithing, Domestic AIR Tightness Tests in Inverness, Domestic AIR Tightness Tests in Inverurie, Domestic AIR Tightness Tests in Ipswich, Domestic AIR Tightness Tests in Irchester, Domestic AIR Tightness Tests in Ireland, Domestic AIR Tightness Tests in Irlam, Domestic AIR Tightness Tests in Irthlingborough, Domestic AIR Tightness Tests in Irvine, Domestic AIR Tightness Tests in Isle of Arran, Domestic AIR Tightness Tests in Isle of Scilly, Domestic AIR Tightness Tests in Isle of Skye, Domestic AIR Tightness Tests in Isleworth, Domestic AIR Tightness Tests in Islington, Domestic AIR Tightness Tests in Iver, Domestic AIR Tightness Tests in Ivybridge,