Offices Nationwide 

Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.

Air Leaking Testing Across the UK

What Air Permeability Rating Do I Need?

The air tightness rating of a property is not a fixed figure. This is set by the design SAP Calculation carried out (please contact us if you also require a SAP Calculation in the UK ). However the worst acceptable standard for air tightness is 10 m³/(h.m²) which resembles the amount of uncontrolled air that's leaking from the dwelling. However this does not mean that it would pass the SAP Calculations Design Air Permeability standard. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.

Why E2 Consultants?

E2 Consultants offer a range of services from desktop reviews of drawings to pre test inspections on site to advice on air tightness, how to improve and what needs to be completed and sealed for the testing to take place successfully.

For a quote or for more information, call our air tightness / pressure testing consultants in the UK on 0800 043 8100 or email us on @e2consultants.co.uk

All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, must have a passing air leakage certificate before the property can be passed off by building regulations.

At E2 Consultants we offer Air Leakage Testing throughout the UK and surrounding areas. Our experienced air leakage testing consultants will also be happy to offer advice on the best ways to gain your target rating.

When Should The Test Take Place?

The air leakage should be completed once the building is completed. All doors and windows in place, all skirting boards sealed, traps filled with water and any penetrations through the envelope of the building need to be sealed. Please find checklist within the downloads section of the website which provide a comprehensive list of requirements. People who follow this checklist have a much higher change of passing the air test first time.

What Does An Air Leakage Test in the UK Involve?

Air tests cannot be carried out if the wind speed is more than 13mph - 3 metres per second is the ideal wind speed when undertaking an air test in the UK. An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results.

Whilst the air tightness test is being undertaken, furniture will not be affected but smaller items such as paper must be held down or removed completely so they're not blown about. The pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut.

There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.

How Many Properties Need An Air Tightness Test?

According to Part L1a, an air pressure test needs to be undertaken on 50% of all dwelling types or three units of each type depending on which value is smaller. A block of flats is considered as a separate development and should be treated as such no matter on the number of blocks on the site. Furthermore, the testing should be done on the first batch of each type of dwelling to be completed. The need to test multiple versions of each type is to confirm the design and construction procedures are up to code according to Government regulations.

For further Air-Tightness-Testing information for your area, be sure to check out Air-Testing-.co.uk.

E2 Specialist Consultants
August 13 at 1:29pm
Today takes 2 of our engineers, air testing this enormous modular classroom in Tring, It took 4 fans to test this space and unfortunately resulted in a Fail. Remedial sealing will be required to areas that we have identified as leaking cold air infiltration. #preperationiskey

E2 Consultants Delivering compliance solutions for Architects & Developers    Head Office E2 HOUSE, South Park Way, Wakefield 41 Business Park, WF2 0XJ    Questions? Call: 0800 043 8100

» » »
Air Tightness Testing
» Domestic Services » Air Tightness Testing

In Area R

Domestic Air leakage testing in Radcliffe, Domestic Air leakage testing in Radcliffe on Trent, Domestic Air leakage testing in Radlett, Domestic Air leakage testing in Radstock, Domestic Air leakage testing in Rainford, Domestic Air leakage testing in Rainham, Domestic Air leakage testing in Rainham, Domestic Air leakage testing in Rainworth, Domestic Air leakage testing in Ramsbottom, Domestic Air leakage testing in Ramsbury Ridge, Domestic Air leakage testing in Ramsey, Domestic Air leakage testing in Ramsgate, Domestic Air leakage testing in Randalstown, Domestic Air leakage testing in Ravenglass, Domestic Air leakage testing in Rawtenstall, Domestic Air leakage testing in Rayleigh, Domestic Air leakage testing in Reading, Domestic Air leakage testing in Redbourn, Domestic Air leakage testing in Redcar, Domestic Air leakage testing in Redditch, Domestic Air leakage testing in Redhill, Domestic Air leakage testing in Redland, Domestic Air leakage testing in Redruth, Domestic Air leakage testing in Reigate, Domestic Air leakage testing in Renfrew, Domestic Air leakage testing in Retford, Domestic Air leakage testing in Rhayader, Domestic Air leakage testing in Rhoose, Domestic Air leakage testing in Rhuddlan, Domestic Air leakage testing in Rhyl, Domestic Air leakage testing in Rhymney, Domestic Air leakage testing in Richmond, Domestic Air leakage testing in Richmond, Domestic Air leakage testing in Rickmansworth, Domestic Air leakage testing in Ringwood, Domestic Air leakage testing in Ripley, Domestic Air leakage testing in Ripon, Domestic Air leakage testing in Ripple, Domestic Air leakage testing in Risca, Domestic Air leakage testing in Robertsbridge, Domestic Air leakage testing in Roby, Domestic Air leakage testing in Rocester, Domestic Air leakage testing in Rochdale, Domestic Air leakage testing in Rochester, Domestic Air leakage testing in Rochford, Domestic Air leakage testing in Romford, Domestic Air leakage testing in Romsey, Domestic Air leakage testing in Ross on Wye, Domestic Air leakage testing in Rossendale, Domestic Air leakage testing in Rostrevor, Domestic Air leakage testing in Rothbury, Domestic Air leakage testing in Rotherfield, Domestic Air leakage testing in Rotherham, Domestic Air leakage testing in Rotherhithe, Domestic Air leakage testing in Rothesay, Domestic Air leakage testing in Rothwell, Domestic Air leakage testing in Rothwell, Domestic Air leakage testing in Rowlands Castle, Domestic Air leakage testing in Rowledge, Domestic Air leakage testing in Rowley Regis, Domestic Air leakage testing in Royston, Domestic Air leakage testing in Royston, Domestic Air leakage testing in Royton, Domestic Air leakage testing in Rugby, Domestic Air leakage testing in Rugeley, Domestic Air leakage testing in Ruislip, Domestic Air leakage testing in Runcorn, Domestic Air leakage testing in Rushden, Domestic Air leakage testing in Rushwick, Domestic Air leakage testing in Rutherglen, Domestic Air leakage testing in Ruthin, Domestic Air leakage testing in Ryde, Domestic Air leakage testing in Rye, Domestic Air leakage testing in Ryton,