Offices Nationwide 

Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.

Air Leaking Testing Across the UK

When Should The Test Take Place?

For obvious reasons, an air pressure test is generally one of the last surveys to be undertaken once all the walls, windows, doors etc. are complete and sealed to stop any air escaping and prevent drafts through the property. The building envelope will also need to be completed.

How Many Properties Need An Air Tightness Test?

The number of tests required are as follows:

  • 4 or less properties of the same type: one test needed per type
  • More than 4 but less than 40 dwellings of a type: at least two tests of each type
  • More than 40 properties of a type: 5% of each type UNLESS the first 5 get a passing score - then this can be dropped to just 2%

What Does An Air Leakage Test in the UK Involve?

During an air test in the UK the pressure of the building will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut. Furniture will not be affected during the test, but smaller items such as paper must be held down or removed completely so they're not blown about.

Air tests cannot be carried out if the wind speed is more than 13mph - 3 metres per second is the ideal wind speed when undertaking an air test in the UK. An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results.

Employees can still do their job inside a commercial or domestic building in the UK whilst the air test is being carried out, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building. There should be no outside access once the test has begun - which lasts for approximately 90 minutes, so plan accordingly.

Why E2 Consultants?

E2 Consultants offer a range of services from desktop reviews of drawings to pre test inspections on site to advice on air tightness, how to improve and what needs to be completed and sealed for the testing to take place successfully.

For a quote or for more information, call our air tightness / pressure testing consultants in the UK on 0800 043 8100 or email us on @e2consultants.co.uk

All new buildings in England and Wales have had a mandatory requirement since 2006 (2010 in Scotland) that domestic and commercial buildings, must have a passing air leakage certificate before the property can be passed off by building regulations.

At E2 Consultants we offer Air Pressure Testing throughout the UK and surrounding areas. Our experienced air pressure testing consultants will also be happy to offer advice on the best ways to gain your target rating.

What Air Permeability Rating Do I Need?

The air tightness rating of a property is not a fixed figure. This is set by the design SAP Calculation carried out (please contact us if you also require a SAP Calculation in the UK ). However the worst acceptable standard for air tightness is 10 m³/(h.m²) which resembles the amount of uncontrolled air that's leaking from the dwelling. However this does not mean that it would pass the SAP Calculations Design Air Permeability standard. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.

For further Domestic-House-Leakage-Testing information for your area, be sure to check out Air-Testing-.co.uk.

E2 Specialist Consultants
August 13 at 1:29pm
Today takes 2 of our engineers, air testing this enormous modular classroom in Tring, It took 4 fans to test this space and unfortunately resulted in a Fail. Remedial sealing will be required to areas that we have identified as leaking cold air infiltration. #preperationiskey

E2 Consultants Delivering compliance solutions for Architects & Developers    Head Office E2 HOUSE, South Park Way, Wakefield 41 Business Park, WF2 0XJ    Questions? Call: 0800 043 8100

» » »
Domestic House Leakage Testing
» Domestic Services » Domestic House Leakage Testing

In Area E

Domestic Air tightness testing in Eaglescliffe, Domestic Air tightness testing in Eakring, Domestic Air tightness testing in Ealing, Domestic Air tightness testing in Earls Colne, Domestic Air tightness testing in Earls Court, Domestic Air tightness testing in Earlston, Domestic Air tightness testing in Earlswood, Domestic Air tightness testing in Easington, Domestic Air tightness testing in Easingwold, Domestic Air tightness testing in East Bergholt, Domestic Air tightness testing in East Dereham, Domestic Air tightness testing in East Drayton, Domestic Air tightness testing in East Dulwich, Domestic Air tightness testing in East Finchley, Domestic Air tightness testing in East Grinstead, Domestic Air tightness testing in East Ham, Domestic Air tightness testing in East Horsley, Domestic Air tightness testing in East Kilbride, Domestic Air tightness testing in East Peckham, Domestic Air tightness testing in East Preston, Domestic Air tightness testing in Eastbourne, Domestic Air tightness testing in Eastcott, Domestic Air tightness testing in Eastham, Domestic Air tightness testing in Eastleigh, Domestic Air tightness testing in Easton, Domestic Air tightness testing in Eastville, Domestic Air tightness testing in Eastwood, Domestic Air tightness testing in Ebbw Vale, Domestic Air tightness testing in Eccles, Domestic Air tightness testing in Eccleshall, Domestic Air tightness testing in Eccleston, Domestic Air tightness testing in Edenbridge, Domestic Air tightness testing in Edgeware, Domestic Air tightness testing in Edinburgh, Domestic Air tightness testing in Edingley, Domestic Air tightness testing in Edmonton, Domestic Air tightness testing in Effingham, Domestic Air tightness testing in Egham, Domestic Air tightness testing in Eglinton, Domestic Air tightness testing in Egremont, Domestic Air tightness testing in Eldersfield, Domestic Air tightness testing in Elgin, Domestic Air tightness testing in Elland, Domestic Air tightness testing in Ellesmere, Domestic Air tightness testing in Ellesmere Port, Domestic Air tightness testing in Ellon, Domestic Air tightness testing in Elmhurst, Domestic Air tightness testing in Elstead, Domestic Air tightness testing in Elston, Domestic Air tightness testing in Eltham, Domestic Air tightness testing in Ely, Domestic Air tightness testing in Emsworth, Domestic Air tightness testing in Enfield, Domestic Air tightness testing in Enford, Domestic Air tightness testing in England, Domestic Air tightness testing in Enniskillen, Domestic Air tightness testing in Epping, Domestic Air tightness testing in Epsom, Domestic Air tightness testing in Erith, Domestic Air tightness testing in Erskine, Domestic Air tightness testing in Esher, Domestic Air tightness testing in Essington, Domestic Air tightness testing in Eton, Domestic Air tightness testing in Everton, Domestic Air tightness testing in Evesham, Domestic Air tightness testing in Ewell, Domestic Air tightness testing in Exeter, Domestic Air tightness testing in Exford, Domestic Air tightness testing in Exmouth, Domestic Air tightness testing in Eye, Domestic Air tightness testing in Eyemouth, Domestic Air tightness testing in Eynsford,