Offices Nationwide 

Bunny - Part E - 0114 368 0192

The office that covers this area is: Sheffield

Phone Number: 0114 368 0192 Email: bunny@e2consultants.co.uk

Commercial_Sound_Testing_Part_E is sometimes referred to as Commercial Sound & Acoustic Insulation Testing, Commercial Sound Testing, Commercial Part E Compliance, Commercial Acoustic Testing, Commercial Sound Insulation Testing.

In Bunny, E2 Consultants can deliver Sound Insulation Testing for new or refurbished dwellings in compliance with Part E of the Building Regulation.

As part of our service in Bunny we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors.

We actively encourage clients to seek our services at the earliest opportunity as it is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.

Our consultants at Bunny can guide you through the process to ensure the best possible chance of achieving sound test passes. Call 0114 368 0192 or email bunny@e2consultants.co.uk

E2 Consultants in Bunny are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services.

Pre-Completion Testing - The following table outlines the sets of tests that are required for new and converted properties.

Property Types Test Requirements

Dwelling-houses Including bungalows

Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall)

Flats with separating floor but not walls

Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact)

Flats with separating floor and walls

Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne) and 6. bedroom/bedroom (wall, airborne)

Rooms for Residential Purposes

To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances.

For further Part E information for your area, be sure to check out Sound-Testing-Sheffield.co.uk.

E2 Specialist Consultants
August 13 at 1:29pm
Today takes 2 of our engineers, air testing this enormous modular classroom in Tring, It took 4 fans to test this space and unfortunately resulted in a Fail. Remedial sealing will be required to areas that we have identified as leaking cold air infiltration. #preperationiskey

E2 Consultants Delivering compliance solutions for Architects & Developers    Head Office E2 HOUSE, South Park Way, Wakefield 41 Business Park, WF2 0XJ    Questions? Call: 0800 043 8100