E2 Consultants deliver Sound Insulation Testing for new or refurbished dwellings in compliance with Part E of the Building Regulation in Stoke on Trent and nationwide.
As part of our service in Stoke on Trent we can also offer advice on the additional requirements of Approved Document Part E including the control of reverberation in common areas and the performance of internal walls and floors.
We actively encourage clients to seek our services at the earliest opportunity as it is possible that the noise mitigation measures required in some instances, could dictate significant changes to external and internal layouts. Therefore our early involvement could remove the need for costly revisions.
E2 Consultants in Stoke on Trent are specialists in the provision of high quality and practical acoustic consultancy to both the public and private sectors; typically working with residential and commercial developers, architects, planning consultants, industry, local planning authorities and environmental services. Our consultants at Stoke on Trent can guide you through the process to ensure the best possible chance of achieving sound test passes. Call 01782 477 014 or email stoke-on-trent@e2consultants.co.uk
Pre-Completion Testing - The following table outlines the sets of tests that are required for New and Converted properties.
Property Types | Test Requirements |
Dwelling-houses Including bungalows | Normally, one set of tests should comprise of two individual Sound Insulation Tests (SITs)(two airborne tests):1. Living room (wall) And 2.Bedroom (wall) |
Flats with separating floor but not walls | Normally, one set of tests should comprise of four individual SITs (2 x airborn, 2 x impact): 1. Living room (Airborn), 2.Living room (Impact), 3. Bedroom (airborn) and 4. Bedroom (Impact) |
Flats with separating floor and walls | Normally, one set of tests should comprise of six individual SITs (4 x airborne, 2 x impact): 1. living room/living room (floor, airborne), 2. living room/living room (floor, impact), 3. bedroom/bedroom (floor, airborne), 4. bedroom/bedroom (floor, impact), 5. living room/living room (wall, airborne), and 6. bedroom/bedroom (wall, airborne) |
Rooms for Residential Purposes | To conduct a set of tests, the sound insulation between the main rooms should be measured according to the principals set out above for new buildings and material change of use, but adapting them to suit the circumstances. |
For further Domestic Sound Testing Part E information for your area, be sure to check out Sound-Testing-Stoke-on-Trent.co.uk.
Our other services include:
Domestic Sound Testing Part E can also be known as:
Domestic Part E Sound Testing, Part E Sound Testing, Domestic Part E Testing, Domestic Part E Sound Insulation Testing, Domestic Part E, Part E, Sound Testing Part E, Sound Insulation Design Advice, Part E Testing, Part E Sound Insulation Testing,