Offices Nationwide 

Air Testing is sometimes referred to as Domestic Air pressure tests, Domestic Air tightness tests, Domestic Air tests, Domestic Air pressure testing, Domestic Air tightness testing, Domestic Air leakage testing.

Air Leaking Testing Across the UK

What Does An Air Leakage Test Involve?

There should be no outside access once the test has begun for approximately 90 minutes so plan accordingly. Workers can still do their job inside the property, within reason, though may feel some discomfort due to the noise of the fan and the draught that will be felt throughout the building.

During an air test in the UK the pressure of the room will be tested and as such all windows and doors that lead outside must be securely closed to avoid them swinging open and the test being abandoned. Similarly, all internal doors should be wedged open to avoid being slammed shut. Furniture will not be affected during the test, but smaller items such as paper must be held down or removed completely so they're not blown about.

An air test involves placing a large fan, or several fans, to an opening within the property; usually a doorway. The fans will increase and decrease in speed that will in-turn change the building's air pressure and record the results. Please note: an air test cannot be carried out if wind speed is more than 13mph. 3 metres per second is the ideal wind speed when undertaking an air test in the UK.

When Should The Test Take Place?

A building envelope will need to be completed before the air test takes place - which should be one of the last surveys undertaken once all the walls, windows, doors etc. are complete and sealed. This ensures no air will escape and prevent drafts through the property which will in-turn improve your air permeability score.

What Air Permeability Rating Do I Need?

A passing score in the UK is 10 m³/(h.m²) for an air permeability rating which resembles the amount of uncontrolled air that's leaking from the dwelling. Should the test fail, our air tightness team will help you identify where the leakages are happening in the hope that a passing score will be achieved after a re-test.

How Many Properties Need An Air Tightness Test?

The number of tests required are as follows:

  • 4 or less properties of the same type: one test needed per type
  • More than 4 but less than 40 dwellings of a type: at least two tests of each type
  • More than 40 properties of a type: 5% of each type UNLESS the first 5 get a passing score - then this can be dropped to just 2%

Do I Need An Air Leakage Test?

Domestic properties and commercial buildings over a certain size must have a passing air leakage certificate before the property can be handed over following a sale. All new buildings in England and Wales have had this requirement since 2006 and in Scotland this has been mandatory since 2010.

Part L of the Government building regulations explains that on a large plot of new houses that are built to a similar specification, only a sample of the houses will need to be air tested.

Planning your test in advance will help our experience air assessment team covering the UK to determine how many tests you'll need ahead of time per property and will be happy to offer advice on the best ways to gain your air permeability rating.

For further Domestic-Air-Tightness-Testing information for your area, be sure to check out Air-Testing-.co.uk.

E2 Specialist Consultants
August 13 at 1:29pm
Today takes 2 of our engineers, air testing this enormous modular classroom in Tring, It took 4 fans to test this space and unfortunately resulted in a Fail. Remedial sealing will be required to areas that we have identified as leaking cold air infiltration. #preperationiskey

E2 Consultants Delivering compliance solutions for Architects & Developers    Head Office E2 HOUSE, South Park Way, Wakefield 41 Business Park, WF2 0XJ    Questions? Call: 0800 043 8100

» » »
Domestic Air Tightness Testing
» Domestic Services » Domestic Air Tightness Testing

In Area K

Domestic Air leakage testing in Kearsley, Domestic Air leakage testing in Keele, Domestic Air leakage testing in Kegworth, Domestic Air leakage testing in Keighley, Domestic Air leakage testing in Keith, Domestic Air leakage testing in Kellington, Domestic Air leakage testing in Kelso, Domestic Air leakage testing in Kelvedon Hatch, Domestic Air leakage testing in Kempston, Domestic Air leakage testing in Kendal, Domestic Air leakage testing in Kenilworth, Domestic Air leakage testing in Kennington, Domestic Air leakage testing in Kensington, Domestic Air leakage testing in Kentish Town, Domestic Air leakage testing in Kesgrave, Domestic Air leakage testing in Keswick, Domestic Air leakage testing in Kettering, Domestic Air leakage testing in Keynsham, Domestic Air leakage testing in Keyworth, Domestic Air leakage testing in Kidderminster, Domestic Air leakage testing in Kidlington, Domestic Air leakage testing in Kielder, Domestic Air leakage testing in Kilbarchan, Domestic Air leakage testing in Kilbirnie, Domestic Air leakage testing in Kilburn, Domestic Air leakage testing in Kilhampton, Domestic Air leakage testing in Kilkeel, Domestic Air leakage testing in Killin, Domestic Air leakage testing in Killyleagh, Domestic Air leakage testing in Kilmacolm, Domestic Air leakage testing in Kilmarnock, Domestic Air leakage testing in Kilsyth, Domestic Air leakage testing in Kilwinning, Domestic Air leakage testing in Kimberley, Domestic Air leakage testing in King's Langley, Domestic Air leakage testing in Kinghorn, Domestic Air leakage testing in Kinglassie, Domestic Air leakage testing in Kings's Lynn, Domestic Air leakage testing in Kingsbridge, Domestic Air leakage testing in Kingsbury, Domestic Air leakage testing in Kingsbury, Domestic Air leakage testing in Kingsclere, Domestic Air leakage testing in Kingsford, Domestic Air leakage testing in Kingsteignton, Domestic Air leakage testing in Kingston Park, Domestic Air leakage testing in Kingston upon Thames, Domestic Air leakage testing in Kingstone, Domestic Air leakage testing in Kingsweston, Domestic Air leakage testing in Kingswinford, Domestic Air leakage testing in Kingswood, Domestic Air leakage testing in Kington, Domestic Air leakage testing in Kingussie, Domestic Air leakage testing in Kinross, Domestic Air leakage testing in Kintore, Domestic Air leakage testing in Kirdford, Domestic Air leakage testing in Kirkburton, Domestic Air leakage testing in Kirkby, Domestic Air leakage testing in Kirkby in Ashfield, Domestic Air leakage testing in Kirkby Lonsdale, Domestic Air leakage testing in Kirkby Stephen, Domestic Air leakage testing in Kirkcaldy, Domestic Air leakage testing in Kirkcudbright, Domestic Air leakage testing in Kirkdale, Domestic Air leakage testing in Kirkham, Domestic Air leakage testing in Kirkintilloch, Domestic Air leakage testing in Kirkoswald, Domestic Air leakage testing in Kirkwall, Domestic Air leakage testing in Kirriemuir, Domestic Air leakage testing in Kirton, Domestic Air leakage testing in Knaresborough, Domestic Air leakage testing in Knebworth, Domestic Air leakage testing in Knighton, Domestic Air leakage testing in Knottingley, Domestic Air leakage testing in Knotty Ash, Domestic Air leakage testing in Knowle, Domestic Air leakage testing in Knutsford, Domestic Air leakage testing in Kyle of Lochalsh,